MassIVE MSV000082855

Imported Reanalysis Dataset Public PXD003346

Ratio accuracy evaluation and correction using tandem mass tags

Description

The multiplexing capabilities of isobaric mass tag based protein quantification, such as Tandem Mass Tags (TMT) or Isobaric Tag for Relative and Absolute Quantitation (iTRAQ) have dramatically increased the scope of Mass Spectrometry (MS) based proteomics studies. Not only does the technology allow for the simultaneous quantification of multiple samples in a single MS injection, but its seamless compatibility with extensive sample pre-fractionation methods allow for comprehensive study of complex proteomes. However, reporter ion based quantification has often been criticized for limited quantification accuracy due to interference from co-eluting peptides and peptide fragments. In this study, we investigate the extent of this problem and propose an effective and easy-to-implement remedy relying on spiking a 6-protein calibration mixture to the samples subject to relative quantification. Our ratio adjustment approach was evaluated on a large scale TMT 10-plex dataset derived from cancer cell lines with chromosome instability. Furthermore, we analyzed a complex 2-proteome artificial sample mixture and investigated the precision of TMT and precursor ion intensity based Label Free Quantification. Comparing the two methods we observed that the isobaric tag based quantification workflow, due to its superior precision, was able to confirm more and smaller protein abundance changes, at a fixed False Positive Rate. [dataset license: CC0 1.0 Universal (CC0 1.0)]

Keywords: Tandem mass tags ; quantitative mass spectrometry ; HCD ; label-free quantification

Contact

Principal Investigators:
(in alphabetical order)
Alexander Schmidt, Biozentrum, Universtiy of Basel, 4056 Basel, Switzerland, N/A
Submitting User: ccms

Publications

Ahrné E, Glatter T, Viganò C, Schubert Cv, Nigg EA, Schmidt A.
Evaluation and Improvement of Quantification Accuracy in Isobaric Mass Tag-Based Protein Quantification Experiments.
J. Proteome Res. 2016 Aug 5;15(8):2537-47. Epub 2016 Jul 7.

Number of Files:
Total Size:
Spectra:
Subscribers:
 
Owner Reanalyses
Experimental Design
    Conditions:
    Biological Replicates:
    Technical Replicates:
 
Identification Results
    Proteins (Human, Remapped):
    Proteins (Reported):
    Peptides:
    Variant Peptides:
    PSMs:
 
Quantification Results
    Differential Proteins:
    Quantified Proteins:
 
Browse Dataset Files Browse Results
 
FTP Download Link (click to copy):

- Dataset Reanalyses


+ Dataset History


Click here to queue conversion of this dataset's submitted spectrum files to open formats (e.g. mzML). This process may take some time.

When complete, the converted files will be available in the "ccms_peak" subdirectory of the dataset's FTP space (accessible via the "FTP Download" link to the right).
Number of distinct conditions across all analyses (original submission and reanalyses) associated with this dataset.

Distinct condition labels are counted across all files submitted in the "Metadata" category having a "Condition" column in this dataset.

"N/A" means no results of this type were submitted.
Number of distinct biological replicates across all analyses (original submission and reanalyses) associated with this dataset.

Distinct replicate labels are counted across all files submitted in the "Metadata" category having a "BioReplicate" or "Replicate" column in this dataset.

"N/A" means no results of this type were submitted.
Number of distinct technical replicates across all analyses (original submission and reanalyses) associated with this dataset.

The technical replicate count is defined as the maximum number of times any one distinct combination of condition and biological replicate was analyzed across all files submitted in the "Metadata" category. In the case of fractionated experiments, only the first fraction is considered.

"N/A" means no results of this type were submitted.
Originally identified proteins that were automatically remapped by MassIVE to proteins in the SwissProt human reference database.

"N/A" means no results of this type were submitted.
Number of distinct protein accessions reported across all analyses (original submission and reanalyses) associated with this dataset.

"N/A" means no results of this type were submitted.
Number of distinct unmodified peptide sequences reported across all analyses (original submission and reanalyses) associated with this dataset.

"N/A" means no results of this type were submitted.
Number of distinct peptide sequences (including modified variants or peptidoforms) reported across all analyses (original submission and reanalyses) associated with this dataset.

"N/A" means no results of this type were submitted.
Total number of peptide-spectrum matches (i.e. spectrum identifications) reported across all analyses (original submission and reanalyses) associated with this dataset.

"N/A" means no results of this type were submitted.
Number of distinct proteins quantified across all analyses (original submission and reanalyses) associated with this dataset.

Distinct protein accessions are counted across all files submitted in the "Statistical Analysis of Quantified Analytes" category having a "Protein" column in this dataset.

"N/A" means no results of this type were submitted.
Number of distinct proteins found to be differentially abundant in at least one comparison across all analyses (original submission and reanalyses) associated with this dataset.

A protein is differentially abundant if its change in abundance across conditions is found to be statistically significant with an adjusted p-value <= 0.05 and lists no issues associated with statistical tests for differential abundance.

Distinct protein accessions are counted across all files submitted in the "Statistical Analysis of Quantified Analytes" category having a "Protein" column in this dataset.

"N/A" means no results of this type were submitted.
This dataset may not contain all raw spectra data as originally deposited in PRIDE. It has been imported to MassIVE for reanalysis purposes, so its spectra data here may consist solely of processed peak lists suitable for reanalysis with most software.