MassIVE MSV000084194

Partial Public

GNPS- HRGC-EI-MS HRGC-PCI-MS HRGC-NCI-MS oF NIST SRM 1950 Human Plasma

Description

Gas chromatography-mass spectrometry (GC-MS) platforms are typically run in electron ionization (EI) mode for mass spectral matching and metabolite annotation. With the advent of high resolution mass spectrometry (HRMS), soft ionization techniques such as chemical ionization (CI) may provide additional coverage for compound identification. We evaluated NIST SRM 1950 pooled plasma reference sample using a HRGC-MS instrument [GC-Orbitrap-MS with electron ionization (EI), positive chemical ionization (PCI), and negative CI (NCI) capabilities) for metabolite annotation and quantification to assess the suitability of the platform for routine discovery metabolomics. Using both open source and vendor workflows, we validated the spectral matches with an in-house spectral library (Wake Forest CPM GCMS spectral and retention time libraries) of EI-MS and CI-MS/MS spectra obtained from chemical standards. We confidently [metabolomics standards initiative (MSI) confidence level 2] identified 263, 93, and 65 metabolites using EI, PCI, and NCI modes, respectively, of which 270 metabolites (64%) were validated using our Wake Forest CPM GCMS spectral libraries. When compared to published LC-MS-based efforts using the same NIST SRM 1950 plasma sample, there was only 17% overlap between the two platforms. In addition, the metabolomics analysis of community approved standard human plasma demonstrated the ability of EI- and CI-MS modes of analysis using a HRGC-MS platform to enable reproducible and interoperable spectral matching. [doi:10.25345/C5DH25] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Keywords: metabolomics ; chemical ionization ; GC-MS ; gas chromatography ; high resolution ; orbitrap ; SRM ; NIST ; plasma ; human

Contact

Principal Investigators:
(in alphabetical order)
Biswapriya Misra, Wake Forest University School of Medicine, USA
Michael Olivier, Wake Forest University School of Medicine, USA
Submitting User: biswamisra
Number of Files:
Total Size:
Spectra:
Subscribers:
 
Owner Reanalyses
Experimental Design
    Conditions:
    Biological Replicates:
    Technical Replicates:
 
Identification Results
    Proteins (Human, Remapped):
    Proteins (Reported):
    Peptides:
    Variant Peptides:
    PSMs:
 
Quantification Results
    Differential Proteins:
    Quantified Proteins:
 
Browse Dataset Files
 
FTP Download Link (click to copy):

- Dataset Reanalyses


+ Dataset History


GNPS content goes here (MSV000084194 [task=c7e41259f1664313bb5642e527b8b65c])
Click here to queue conversion of this dataset's submitted spectrum files to open formats (e.g. mzML). This process may take some time.

When complete, the converted files will be available in the "ccms_peak" subdirectory of the dataset's FTP space (accessible via the "FTP Download" link to the right).
Number of distinct conditions across all analyses (original submission and reanalyses) associated with this dataset.

Distinct condition labels are counted across all files submitted in the "Metadata" category having a "Condition" column in this dataset.

"N/A" means no results of this type were submitted.
Number of distinct biological replicates across all analyses (original submission and reanalyses) associated with this dataset.

Distinct replicate labels are counted across all files submitted in the "Metadata" category having a "BioReplicate" or "Replicate" column in this dataset.

"N/A" means no results of this type were submitted.
Number of distinct technical replicates across all analyses (original submission and reanalyses) associated with this dataset.

The technical replicate count is defined as the maximum number of times any one distinct combination of condition and biological replicate was analyzed across all files submitted in the "Metadata" category. In the case of fractionated experiments, only the first fraction is considered.

"N/A" means no results of this type were submitted.
Originally identified proteins that were automatically remapped by MassIVE to proteins in the SwissProt human reference database.

"N/A" means no results of this type were submitted.
Number of distinct protein accessions reported across all analyses (original submission and reanalyses) associated with this dataset.

"N/A" means no results of this type were submitted.
Number of distinct unmodified peptide sequences reported across all analyses (original submission and reanalyses) associated with this dataset.

"N/A" means no results of this type were submitted.
Number of distinct peptide sequences (including modified variants or peptidoforms) reported across all analyses (original submission and reanalyses) associated with this dataset.

"N/A" means no results of this type were submitted.
Total number of peptide-spectrum matches (i.e. spectrum identifications) reported across all analyses (original submission and reanalyses) associated with this dataset.

"N/A" means no results of this type were submitted.
Number of distinct proteins quantified across all analyses (original submission and reanalyses) associated with this dataset.

Distinct protein accessions are counted across all files submitted in the "Statistical Analysis of Quantified Analytes" category having a "Protein" column in this dataset.

"N/A" means no results of this type were submitted.
Number of distinct proteins found to be differentially abundant in at least one comparison across all analyses (original submission and reanalyses) associated with this dataset.

A protein is differentially abundant if its change in abundance across conditions is found to be statistically significant with an adjusted p-value <= 0.05 and lists no issues associated with statistical tests for differential abundance.

Distinct protein accessions are counted across all files submitted in the "Statistical Analysis of Quantified Analytes" category having a "Protein" column in this dataset.

"N/A" means no results of this type were submitted.
This dataset may not contain all raw spectra data as originally deposited in PRIDE. It has been imported to MassIVE for reanalysis purposes, so its spectra data here may consist solely of processed peak lists suitable for reanalysis with most software.